Cyclone Intake

Posted in Intake by admin on January 7, 2010 No Comments yet

Cyclone Intake

POWERPLUS CYCLONE 53001 INTAKE MANIFOLD BB CHEVY POWERPLUS CYCLONE 53001 INTAKE MANIFOLD BB CHEVY Paypal US $99.95 1d 8h 2m
INTAKE MANIFOLD POWERFORCEPLUSSBC VORTEC CYCLONE INTAKE MANIFOLD POWERFORCEPLUSSBC VORTEC CYCLONE Paypal US $142.00 8d 10h 56m
INTAKE MANIFOLD POWERFORCEPLUS SBC CYCLONE EGR INTAKE MANIFOLD POWERFORCEPLUS SBC CYCLONE EGR Paypal US $151.00 8d 10h 55m
INTAKE MANIFOLD POWERFORCEPLUS BBC CYCLONE INTAKE MANIFOLD POWERFORCEPLUS BBC CYCLONE Paypal US $157.00 8d 10h 51m
SBC 57 95 Chevy Dual Plane Intake Manifold Satin SBC 57 95 Chevy Dual Plane Intake Manifold Satin Paypal US $139.99 21d 2h 4m
52007 Professional Products CYCLONE SBC Intake Manifold 52007 Professional Products CYCLONE SBC Intake Manifold Paypal US $164.99 20d 2h 42m
53001 Professional Products Cyclone BBC Intake Manifold 53001 Professional Products Cyclone BBC Intake Manifold Paypal US $184.99 20d 2h 48m
SBC 57 95 Chevy Dual Plane Intake Manifold Polished SBC 57 95 Chevy Dual Plane Intake Manifold Polished Paypal US $179.99 21d 2h 7m
SBC 57 95 Chevy Airgap Intake Manifold Satin SBC 57 95 Chevy Airgap Intake Manifold Satin Paypal US $179.99 21d 2h 14m
BBC 65 90 Chevy Dual Plane Intake Manifold Satin BBC 65 90 Chevy Dual Plane Intake Manifold Satin Paypal US $199.99 21d 2h 29m
Professional Products Intake Manifold 52010 Professional Products Intake Manifold 52010 Paypal US $249.99 14d 2h 33m
BBC 65 90 Chevy Dual Plane Intake Manifold Polished BBC 65 90 Chevy Dual Plane Intake Manifold Polished Paypal US $209.99 21d 2h 38m
52000 Professional Products CYCLONE SBC Intake Manifold 52000 Professional Products CYCLONE SBC Intake Manifold Paypal US $199.99 23d 6h 2m
53000 Professional Products Cyclone BBC Intake Manifold 53000 Professional Products Cyclone BBC Intake Manifold Paypal US $239.99 20d 5h 4m
SBC 57 95 Chevy Airgap Intake Manifold Polished SBC 57 95 Chevy Airgap Intake Manifold Polished Paypal US $239.99 21d 2h 15m
   1

Professional Products 53001 Cyclone Satin Intake Manifold Professional Products 53001 Cyclone Satin Intake Manifold
Sale Price: $169.75

BMC AIR FLTR BUELL FM24015 BMC AIR FLTR BUELL FM24015
List Price: $70.95
Sale Price: $60.00

BMC Air Filters Intake Bmc air filters bmc air filter buell #fm24015 Photo`s are for reference only. Please read item title carefully.

Professional Products 52010 CYCLONE+PLUS Polished Intake Manifold with Kit Professional Products 52010 CYCLONE+PLUS Polished Intake Manifold with Kit
Sale Price: $226.32

Professional Products 53000 Cyclone Polished Intake Manifold Professional Products 53000 Cyclone Polished Intake Manifold
Sale Price: $209.33

Professional Products 52000 Cyclone Polished Intake Manifold Professional Products 52000 Cyclone Polished Intake Manifold
Sale Price: $188.94

Professional Products 52001 Cyclone Satin Intake Manifold Professional Products 52001 Cyclone Satin Intake Manifold
Sale Price: $142.91

Professional Products 52009 CYCLONE Satin Intake Manifold with Exhaust Gas Recirculation Professional Products 52009 CYCLONE Satin Intake Manifold with Exhaust Gas Recirculation
Sale Price: $178.15

Design of Local Exhaust Systems for Industrial Air Cleaning

Local exhaust ventilation systems are designed to capture airborne chemicals at the source of generation and remove contaminants from the work area. When a local exhaust system does its job your workers are healthy and productive. It usually consists of:

- hoods for capturing the contaminant

- ducts for transporting the contaminant

- air cleaner for removing contaminants from the air stream

- fan to create airflow in the system

- stack to discharge the air outside the workplace.

To design a Local Exhaust System we must know the:

* physical state of the chemical (Is it a dust, mist, fume, gas or vapor ?),

* chemical's toxicity and applicable exposure limits,

* physical properties of the chemical (Vapor pressure, boiling point, flash point),

* routes of worker exposure -- inhalation, ingestion, skin contact,

* how, where and when the chemical is used,

* how the worker does their job.

HOOD DESIGN

A well-designed hood is the most important component of an effective LEVS. The hood must be positioned so that it does not pull contaminated air through the worker's breathing zone. It should be easy to use and not interfere with the job that the worker is trying to do. It should be positioned as close to the point of contaminant generation as possible. The further it is from the point where the chemical is released into the air, the more airflow is required to capture the contaminant.

AIR VOLUME AND CAPTURE VELOCITY

The air volume (cubic feet per minute) that must be exhausted by LEVS is determined by the type of hood, the distance of the hood from the source of the contaminant and the velocity needed to capture the contaminant (Capture Velocity). Capture velocity for a hood is determined by the properties of the chemical and how it is being used. Examples of capture velocities are shown in Table 1.

MAKE UP AIR

Air will only be exhausted to the extent that air enters the workplace. If you don't provide make up air in the amount at least equal to the amount of air being exhausted, your LEVS will not work properly and the workplace will be very drafty, doors will be difficult to open, and furnaces, heaters or other combustion equipment may back draft.

TRANSPORT VELOCITY AND DUCT SIZE

Once a contaminant is captured by the hood it moves into the duct system. The velocity in the duct must be sufficient to transport the contaminant through the LEVS. The velocity in the duct necessary to carry the contaminant through the system is referred to as the transport velocity. The heavier the contaminant the higher the velocity needed for transport. Some examples of transport velocities for different contaminants are shown in Table 2. Once you know the airflow volume and transport velocity needed for a LEVS, the duct size can be calculated using the formula shown in Table 3.

sTREAMLINE AIR FLOW

Local exhaust systems should always use round ducts, because airflow is more uniform and streamlined, which makes the system more efficient and provides better transport for contaminants. The duct runs should be as straight as possible; curves should be smooth and gradual; and an elbow should have a radius of 2 to 2.5 times the duct diameter. Branch entries into the main duct should be at an angle of 45?; there should be no 90? entries. All changes in size should be smooth and gradual.

STACKS

A stack should discharge contaminated air vertically upward and away from the building. Stacks should be located as far from air intake units as possible to prevent reintroduction of contaminated air into the building. The top of the stack should be 1.3 to 2 times the building height above the ground. Avoid exhausting air out of the sides of buildings. The pressure of prevailing winds blowing into the exhaust can severely affect the performance of the LEVS.

FAN SELECTION

The fan you select for your LEVS should be based on the needs of the system. It should not only deliver the volume of air (in cubic feet per minute) necessary to capture the contaminant but be able to do so against the resistance to airflow in the system. The resistance to airflow is measured in inches of water and is usually referred to as static pressure losses. Static pressure losses in LOCAL EXHAUST SYSTEM are determined by the:

- size of the duct,

- roughness of the duct material,

- number and type of elbows, entries, and changes in size,

- type of air cleaner,

- type of hood,

- volume of air flowing in the system,

- stack design.
 
It should be clear from this list that a fan cannot possibly be selected successfully until the system has been designed.

SYSTEM INSTALLATION

Insist that you get a system installed as designed, with round ducts and smooth streamlined airflow. Since a rough duct increases static pressure losses and requires a larger fan, you should keep the use of a flexible duct, which is very rough, to a minimum. Use a flexible duct only where you need flexibility and use as little of it as possible.

Fans will operate more efficiently if they are installed with a length of straight duct entering and leaving the fan. A rule of thumb is to provide a straight run of duct at least six duct diameters long on the entrance side of the fan and at least two duct diameters long on the exit side. After installing the system, measure to ensure that the LEVS delivers the airflow volume and velocity that is needed to do the job.

For additional information please refer to http://nis-co.com/dustcollector/Index.html.

Oleg Tchetchel
Process Engineer
Canadian Air Systems
http://www.nis-co.com/fumeextractor/Index.html
http://www.nis-co.com/scrubber/Index.html

About the Author

Oleg Tchetchel
Designer of Air Moving Systems
Canadian Air Systems

http://nis-co.com/contact/Index.html

Does the Cyclone Air work?

I saw an infomercial on TV last night for this thing that is called Cyclone Air and it goes in your intake of your vehicle and it makes the air that comes in, spin into a cyclone and will mix with your fuel better in which increases fuel milage by about 12%-15% and will give you about 10+ more horse. My question is, does anyone have it and does it actually work, cuz I'm a sucker for things I see on TV although most is just a false advertisement and I don't wanna fall for it and waste my money...So who has one and does it work? Is it worth the money?

http://reviews.ebay.com/BEWARE-of-scams-ripoffs-unscrupulous-sellers_W0QQugidZ10000000001273057?ssPageName=BUYGD:CAT:-1:SEARCH:6

Cyclone Intake Mod

NASA ISS On-Orbit Status 3 June 2010
All ISS systems continue to function nominally, except those noted previously or below.