Ground Wire

Posted in General by admin on February 5, 2010 No Comments yet

Ground Wire

eBay Logo  

Buddy Club Condenser Ground System (Earthing Kit) Wires


Buddy Club Condenser Ground System (Earthing Kit) Wires


$120.00


Buddy Club Condenser Ground System (Earthing Kit) Wires


Buddy Club Condenser Ground System (Earthing Kit) Wires


$120.00


Petsafe PRF-304W Deluxe In-Ground Radio Fence w/ Wire & Flags


Petsafe PRF-304W Deluxe In-Ground Radio Fence w/ Wire & Flags


$149.97


NO fences, chains or cages! PetSafe Containment System, the world’s best-seller and “BEST” rated, has it under control. This Radio Fence System works. It establishes an unseen boundary that your pet quickly learns to respect. Fast, easy and good for your dog: Waterproof UltraLight receiver collar weighs just 1 1/2 ozs., adjusts to fit necks 6″ to 28″. It delivers the corrective electrical impulse …

Petsafe PRF-3004W In-Ground Radio Fence System with Wire and Flags PRF-3004W


Petsafe PRF-3004W In-Ground Radio Fence System with Wire and Flags PRF-3004W


$131.36


System will cover up to 10 acres with additional wire and flags (refer to model No. PRFA 500). Ultralight receiver comes with a 500′ spool of wire, an adjustable collar, manual, and video CD. Boundary control switch settings: A = greater than 2400′; B = up to 1300′; C = 2400′. 1 level of correction. Should be installed in a dry and protected enviroment. Boundary wire must must be copper and must b…

Harold Imports Chopstir


Harold Imports Chopstir


$5.59


It chops! It stirs! In a fraction of the time. The Chop Stir chops hamburger, ground meat, soft fruits and vegetables and pie shell crumbs. It is great for stirring frozen juice concentrate and soups. Safe to use right in the pan over medium-high heat (do not leave in pan while not in use). Dishwasher Save. Length: 10 inches…

Explicits


Explicits


$1.17


This band gets right to the point! Pulls you in, spits you out, leaves you wanting more. A pure adrenaline rush….

The Meter Glows


The Meter Glows


$11.58



Stolen Music: New Compositions by Matthew Davidson


Stolen Music: New Compositions by Matthew Davidson


$6.00



Welch Allyn Model 112085-1 - Wire Assy, 4.25 Large (Ground)


Welch Allyn Model 112085-1 – Wire Assy, 4.25 Large (Ground)


$16.37


Welch Allyn Model 112085-1 – Wire Assy, 4.25″ Large (Ground)…

Welch Allyn Model 441055 - Ground Wire, Trans


Welch Allyn Model 441055 – Ground Wire, Trans


$12.02


Welch Allyn Model 441055 – Ground Wire, Trans…

Welch Allyn Model 443094-1 - Ground Wire Cover Plate


Welch Allyn Model 443094-1 – Ground Wire Cover Plate


$9.91


Welch Allyn Model 443094-1 – Ground Wire Cover Plate…

BullDog Winch Wiring 7.5ft Winch Wiring Kit - (4 GA) double power & ground wire with loop ends, quick connnector & 12pc cable ties


BullDog Winch Wiring 7.5ft Winch Wiring Kit – (4 GA) double power & ground wire with loop ends, quick connnector & 12pc cable ties


$43.99


Bull dog winch company offers a variety of wiring and accessories for winches including complete winch wiring kits. 7.5ft Winch Wiring Kit – (4 GA) double power & ground wire with loop ends, quick connnector & 12pc cable ties…

What Is Knob And Tube Wiring?

 

What is Knob and Tube Wiring

 

Knob and tube was one of the most hazardous wiring methods ever used because it is an ungrounded system.  What does this mean? Electricity begins at the circuit breaker where it flows through the hot or “ungrounded” conductor and comes back on the neutral or “grounded” conductor completing its path.  This system works well in theory until you become a path to ground.  

 

Recently, an alternate path to ground is required by either using the outer metal sheathing of wire or conduit or by placing an actual ground or “grounding” conductor within the wire assembly.  This provides an alternate path to ground tripping the circuit breaker disallowing YOU to become that path. 

 

This might not sound very likely, but it is actually not hard to accomplish.  If you are in your basement and pull the pull chain of an ungrounded light fixture, you can easily become the path to ground.  The same can happen with any ungrounded light switch or receptacle.

 

The National Electrical Code permits ungrounded receptacles to be two-pronged instead of three-pronged.  The reason the code allows this is because the absence of a third prong or “grounding” prong is meant to prevent people from plugging in equipment that needs to be grounded but instead most people break off  the grounding prong of an extension cord or power tool making it extremely unsafe. 

 

Another way this may be corrected is by installing a ground fault receptacle, which measures the current going through the plug itself and will trip if there is an unbalanced current, protecting the end user.  While this is the safer “quick fix”, the potential homeowner is still left with a knob and tube system.

 

Some may think that they are safe because they have installed GFCI receptacles but another problem exists.  When knob and tube circuits run, they would pull a neutral wire from whichever circuit was closest.  This means is that there is an abundance of current overloading the neutral conductor that is not connected to a circuit breaker allowing that conductor to overheat and not open the circuit.

 

Excessive heat to a conductor will cause the insulation to breakdown.  Over time, the outer coating will become frail and brittle exposing the bare copper conductor.  Once this happens, it is only a matter of time before you need an experienced electrician.

 

About the Author

Dan Stroup – NJ Electrical Contractor
Licensed – Insured – Bonded
www.superiorwirework.com

Leave a Comment